63 Safety systems

Do you work with Telecom, Data, or security? Ahlsell helps you find the products within security and integration. Whether you work in electrical engineering, burglar alarms, or access systems, we have the range you need. Here you will find fiber optics, telephony, antenna material, and power supply for installation, along with smart solutions from major suppliers. Explore our wide selection here in the online store or visit your nearest Ahlsell store.

Optical smoke alarm 10-year battery connectable a-collection
a-collection
Optical smoke alarm 10-year battery connectable a-collection
Art. no.: 6302618
Optical wireless linkable fire alarm with 10-year battery. It has a test and pause button and a diode that indicates function with 1 blink/min. Approved according to EN 14604:2005 + AC: 2008, with a sound pressure of 85dbm. Safety function The non-replaceable battery is integrated into the mounting plate. Optical fire alarms have an advanced photocell system that detects smoke particles. The optical smoke detector is best when it comes to detecting smoldering fires with visible smoke particles. Supplied with 10-year battery, mounting plate, screw, plug and user manual. The number of fire alarms that can be connected is limited by the range of the radio signal. In order for the connected fire alarm to be affected, it must have direct contact with the fire alarm that sounds the alarm, the alarm is not forwarded. The range is >100m in clear view but is limited by walls and objects. Recommended maximum number of connected units 12.
Alarm panel LAN 63 & LAN 64, Rutab
Rutab
Alarm panel LAN 63 & LAN 64, Rutab
Art. no.: 6390202
LAN 63 includes programmability for operation or alarms as a standard feature.
LAN 64 (Slave panel)
Connection of a master panel and slave panel is quick and easy with the flat cable included with the LAN 64 slave panel. Group alarms from all slaves are indicated and acknowledged on the LAN 63 master panel.

• Small format, only 129 x 70 x 27 mm (recess depth 20 mm).
• 12 alarm inputs:
• All incoming cables are connected to plug-in screw blocks, which simplifies the installation process.
• 2 potential-free switching group alarm outputs, priority A or B.
• LED indication on the module front.
• Each alarm input is individually programmable:
• Alarm delay up to 60 minutes.
• for closing or breaking alarm contacts (NO/NC).
• selectable as alarm (red diode) or operation indication (yellow diode).
• All alarm inputs have memory and blink functions.
• The front of the panel is equipped with reset and LED test.
• Buzzer alarm outputs trigger an alarm in case of voltage loss.
• May be combined with a relay box (LAN 65-2), which provides 12 galvanically free contacts for parallel alarm transmission.
Alarm Transmitter/Relay 9065
Ontech
Alarm Transmitter/Relay 9065
Art. no.: 6390999
Ontech 9065, the successor to 6390141 (Ontech GSM 9025) alarm transmitter and remote relay that communicates via the 4G network. SIM card is attached. Communication directly via the Internet. Does not need wifi. Cash cards can be used and then communication by SMS. The device is powered with the supplied adapter or 9-30VDC alternatively 24 VAC.Output is a potential-free relay.Temperature range- 40 to + 55 degrees Celsius.Overheat protection by software, shuts off the relay if it gets over 70 degrees inside the unit.Programmable via the Ontech Control web interface.Can with short-range radio control up to 7 extra relays (Ontech GSM Relay 9015, (63 901 79). Duplex function on extra relays that can also be controlled with a timer function. Two alarm inputs (NO or NC). Always alerts by email and with SMS as an option according to the programmable alarm list. Indicates the current temperature.Temperature monitor that automatically alarms above or below the set temperature.External temperature sensor as an accessory.Can be used as a thermostat, i.e. the set temperature controls the relay. Internal extra battery included. Warns with the battery connected in the event of a power failure and when the power returns. Can report and alarm for current 4-20 mA.
A GPS receiver can be connected and GPS movement alarms can be set. Reports on position, speed and direction can be obtained. Many functions can be programmed in Ontech Control.
Fire detector, wireless, KI-9XRLB, Kamic
Kamic
Fire detector, wireless, KI-9XRLB, Kamic
Art. no.: 6302876
Wireless fire alert, with 10-year battery.
All units communicate wirelessly. When a detector sounds the alarm,a coded alarm signal is sent to all units in the system within radio range. The range can be doubled with the repeat function. The built-in 10-year battery guarantees operation for at least ten years. Detectors set on the omni-channel ‘0’can also send and receive signals from all the other channels; this is ideal if surveillance is desired in common spaces such as stairs or cellars, etc. With a total of 240 channels, this detector can be used in large tenements without risk of overhearing.
16x15 channels and 1 omnichannel.
Range 200m with repeater.
Built-in 10-year lithium battery.
Very easy installation.
Noise memory and noise identification.
Approved in accordance with SS- EN 14604-2005/AC 2008.
Supplied with: built-in 10-year lithium battery, bolts,screws, and instructions in Swedish.
Alarm transmitter 4G Neo
DSC
Alarm transmitter 4G Neo
Art. no.: 6310314
Integrated alarm transmitter LE2080 for the NEO alarm systems for IP communication via 4G. High reliability as both 2G, 3G and 4G networks can be used. Can be used as primary or secondary alarm transmitter in the system. Full support for DLS remote programming. Handles SIA and Contact ID alarm formats and supports SMS functions and Connect Alarm App. The LE2080-EU handles image transmission to the alarm center and App from Neo camera detectors. Mounted in the central unit's main enclosure with the accompanying mounting plate and easily connected with the connection cable. Antenna included. Can be programmed via the control panel or with the DLS5 program. Current consumption: 100mA min - 400mA max. Temperature range: -10 to +55 °C. SBSC approved in alarm class 2.
Fire alarm 230V OPT KI-11B
Kamic
Fire alarm 230V OPT KI-11B
Art. no.: 6303346
Fire alarm for connection to the 230V network. With the replaceable backup battery, 3x1.5V AAA, operation is ensured in the event of a power failure. Connection of 16 detectors with cable as standard and connected with phase, neutral and signal conductors, max 2.5mm2 and 250m. With a radio module as an accessory, connection can be made wirelessly.You can also combine wired and wireless in the same system heat detector E6303347. Easy to install over a ceiling box. With the FastFix system, it is easily attached to an installed base, E6303349, for controlling external equipment such as door closers and wireless control panel E6303351, which facilitates testing at high ceilings EN14604:2005/AC:2008 with sound pressure of 85dBm at 3 meters Supplied with mounting base, screw and plug, built-in rechargeable battery and Swedish user manual.

6304283 = Note! This model replaces the predecessor KI-10B but they do not communicate with each other. If the old KI-10Bs are connected with wires or wirelessly, all old KI-10s need to be replaced with new KI-11s. However, the old socket can be used.
Alarm transmitter/relay Ontech 9060
Alarm transmitter/relay Ontech 9060
Art. no.: 6390549
Ontech 9060, the successor to 6390292 (Ontech GSM 9040) alarm transmitter and remote relay (230V socket 16A 230V) that communicates via the 4G mobile network. Cash cards can be used, Switched unit. Overheat protection by software, turns off the relay if it gets over 70 degrees inside the unit. Programmed via the Ontech Control portal. Can control up to 7 additional relays (Ontech GSM Relay 9010, (63 904 52)) with a short-range radio. Duplex function on additional relays that can also be controlled with a timer function. Two alarm inputs (NO or NC). Alarms with SMS according to programmable phone list. Indicates the current temperature. Frost monitor that automatically alarms above or below the set temperature. External temperature sensor as accessory. Can be used as a thermostat, i.e. set temperature controls the relay. Internal extra battery included. Warns with the battery connected in the event of a power failure and when the power returns.
MC 440 with built-in resistance, Alarmtech
Alarmtech
MC 440 with built-in resistance, Alarmtech
Art. no.: 6309408
MC 440 is a magnetic connector for surface mounting and NC function with 2 pre-mounted resistors of 1K ohm for balanced loop. When installing, select one or both of the resistances to be used, see connection diagram. The connector has a screw terminal with wire cover for easy mounting. With the supplied magnet it works the contact is excellent also on security doors with a very good gap. If you want even greater gaps, the magnet can be replaced by an extra strong magnet, MC 400-MX. Plastic spacers are supplied to the magnetic and contact parts when mounted on steel or to build better distances. The plastic spacers are also available separately, see MC 400-6 and MC 400-7. For thinner plastic spacers, MC 400-3 and MC 400-4 also work. There are also different types of mounting angles, see MC L or MC Z. If different resistance values are desired in the contact, this is good to order.
Fire detector 9V linkable, pause function Kamic
Kamic
Fire detector 9V linkable, pause function Kamic
Art. no.: 6302810
These optical fire alarms can be linked with to 0.75 mm2 wires to form a system – if one alarm is triggered, they all sound an alarm. The test button for the function control and pause function, which lowers sensitivity for 10 minutes, allows for avoiding unnecessary alarms in connection with cooking, for instance. With a pin, you can ensure that the fire alarm cannot be removed from its mount. The battery lock ensures that the fire alarm cannot be mounted without a battery. The mount is black, so the absence of the fire alarm in the ceiling is visible, which is a safety function. Supplied complete with a mounting bracket with a mounting gap of 30-75 mm, 5 mm screws, plugs and a super heavy-duty battery, as well as usage instruction in Swedish.
Showing 52 of 174