Feedback
AhlsellProductsElectricTelecoms, Data, Security 50-6363 Safety systemsAlarm communicationAlarm panel
Rutab
Alarm panel LAN 63 & LAN 64, Rutab
SUPERVISION PANEL MASTER LAN63
Article number: Suppl. article no:
6390202
6390202
to see price and stock
LAN 63 includes programmability for operation or alarms as a standard feature.
LAN 64 (Slave panel)
Connection of a master panel and slave panel is quick and easy with the flat cable included with the LAN 64 slave panel. Group alarms from all slaves are indicated and acknowledged on the LAN 63 master panel.
• Small format, only 129 x 70 x 27 mm (recess depth 20 mm).
• 12 alarm inputs:
• All incoming cables are connected to plug-in screw blocks, which simplifies the installation process.
• 2 potential-free switching group alarm outputs, priority A or B.
• LED indication on the module front.
• Each alarm input is individually programmable:
• Alarm delay up to 60 minutes.
• for closing or breaking alarm contacts (NO/NC).
• selectable as alarm (red diode) or operation indication (yellow diode).
• All alarm inputs have memory and blink functions.
• The front of the panel is equipped with reset and LED test.
• Buzzer alarm outputs trigger an alarm in case of voltage loss.
• May be combined with a relay box (LAN 65-2), which provides 12 galvanically free contacts for parallel alarm transmission.
LAN 64 (Slave panel)
Connection of a master panel and slave panel is quick and easy with the flat cable included with the LAN 64 slave panel. Group alarms from all slaves are indicated and acknowledged on the LAN 63 master panel.
• Small format, only 129 x 70 x 27 mm (recess depth 20 mm).
• 12 alarm inputs:
• All incoming cables are connected to plug-in screw blocks, which simplifies the installation process.
• 2 potential-free switching group alarm outputs, priority A or B.
• LED indication on the module front.
• Each alarm input is individually programmable:
• Alarm delay up to 60 minutes.
• for closing or breaking alarm contacts (NO/NC).
• selectable as alarm (red diode) or operation indication (yellow diode).
• All alarm inputs have memory and blink functions.
• The front of the panel is equipped with reset and LED test.
• Buzzer alarm outputs trigger an alarm in case of voltage loss.
• May be combined with a relay box (LAN 65-2), which provides 12 galvanically free contacts for parallel alarm transmission.
- Article number: 6390202
- Suppl. article no: 6390202
- Material class QS7490
Technical data
- Type: LAN 63
- Information: Voltage: 24 V AC/DC -10% - +20%
Power consumption: operation 40 mA, alarm 95 mA max