Alarm communication

Do you work with Telecom, Data, or security? Ahlsell helps you find the products within security and integration. Whether you work in electrical engineering, burglar alarms, or access systems, we have the range you need. Here you will find fiber optics, telephony, antenna material, and power supply for installation, along with smart solutions from major suppliers. Explore our wide selection here in the online store or visit your nearest Ahlsell store.

Alarm panel LAN 63 & LAN 64, Rutab
Rutab
Alarm panel LAN 63 & LAN 64, Rutab
Art. no.: 6390202
LAN 63 includes programmability for operation or alarms as a standard feature.
LAN 64 (Slave panel)
Connection of a master panel and slave panel is quick and easy with the flat cable included with the LAN 64 slave panel. Group alarms from all slaves are indicated and acknowledged on the LAN 63 master panel.

• Small format, only 129 x 70 x 27 mm (recess depth 20 mm).
• 12 alarm inputs:
• All incoming cables are connected to plug-in screw blocks, which simplifies the installation process.
• 2 potential-free switching group alarm outputs, priority A or B.
• LED indication on the module front.
• Each alarm input is individually programmable:
• Alarm delay up to 60 minutes.
• for closing or breaking alarm contacts (NO/NC).
• selectable as alarm (red diode) or operation indication (yellow diode).
• All alarm inputs have memory and blink functions.
• The front of the panel is equipped with reset and LED test.
• Buzzer alarm outputs trigger an alarm in case of voltage loss.
• May be combined with a relay box (LAN 65-2), which provides 12 galvanically free contacts for parallel alarm transmission.
Alarm Transmitter/Relay 9065
Ontech
Alarm Transmitter/Relay 9065
Art. no.: 6390999
Ontech 9065, the successor to 6390141 (Ontech GSM 9025) alarm transmitter and remote relay that communicates via the 4G network. SIM card is attached. Communication directly via the Internet. Does not need wifi. Cash cards can be used and then communication by SMS. The device is powered with the supplied adapter or 9-30VDC alternatively 24 VAC.Output is a potential-free relay.Temperature range- 40 to + 55 degrees Celsius.Overheat protection by software, shuts off the relay if it gets over 70 degrees inside the unit.Programmable via the Ontech Control web interface.Can with short-range radio control up to 7 extra relays (Ontech GSM Relay 9015, (63 901 79). Duplex function on extra relays that can also be controlled with a timer function. Two alarm inputs (NO or NC). Always alerts by email and with SMS as an option according to the programmable alarm list. Indicates the current temperature.Temperature monitor that automatically alarms above or below the set temperature.External temperature sensor as an accessory.Can be used as a thermostat, i.e. the set temperature controls the relay. Internal extra battery included. Warns with the battery connected in the event of a power failure and when the power returns. Can report and alarm for current 4-20 mA.
A GPS receiver can be connected and GPS movement alarms can be set. Reports on position, speed and direction can be obtained. Many functions can be programmed in Ontech Control.
Alarm transmitter 4G Neo
DSC
Alarm transmitter 4G Neo
Art. no.: 6310314
Integrated alarm transmitter LE2080 for the NEO alarm systems for IP communication via 4G. High reliability as both 2G, 3G and 4G networks can be used. Can be used as primary or secondary alarm transmitter in the system. Full support for DLS remote programming. Handles SIA and Contact ID alarm formats and supports SMS functions and Connect Alarm App. The LE2080-EU handles image transmission to the alarm center and App from Neo camera detectors. Mounted in the central unit's main enclosure with the accompanying mounting plate and easily connected with the connection cable. Antenna included. Can be programmed via the control panel or with the DLS5 program. Current consumption: 100mA min - 400mA max. Temperature range: -10 to +55 °C. SBSC approved in alarm class 2.
Alarm transmitter/relay Ontech 9060
Alarm transmitter/relay Ontech 9060
Art. no.: 6390549
Ontech 9060, the successor to 6390292 (Ontech GSM 9040) alarm transmitter and remote relay (230V socket 16A 230V) that communicates via the 4G mobile network. Cash cards can be used, Switched unit. Overheat protection by software, turns off the relay if it gets over 70 degrees inside the unit. Programmed via the Ontech Control portal. Can control up to 7 additional relays (Ontech GSM Relay 9010, (63 904 52)) with a short-range radio. Duplex function on additional relays that can also be controlled with a timer function. Two alarm inputs (NO or NC). Alarms with SMS according to programmable phone list. Indicates the current temperature. Frost monitor that automatically alarms above or below the set temperature. External temperature sensor as accessory. Can be used as a thermostat, i.e. set temperature controls the relay. Internal extra battery included. Warns with the battery connected in the event of a power failure and when the power returns.
Alarm transmitter Airborne DC Dual, AddSecure
AddSecure
Alarm transmitter Airborne DC Dual, AddSecure
Art. no.: 6390333
Alarm transmitter for alarm transmission where there is a need or requirement for alarm communication via two independent alarm transmission routes. The Airborne DC Dual uses the mobile telephone network along with a fixed IP connection to attain maximum availability and security. The Airborne DC Dual is also designed for serial transmission, e.g. of SIA from burglar alarm central units or ESPA-444 protocol from fire alarm systems. Dial-up protocols based on tone signalling, such as SIA, Contact-ID, and Robofon, are digitalised before alarm transmission. With 16 inputs and 4 relay outputs, the transmitter covers most needs for reliable alarm transmission. Medium and Large are enclosed, the Medium without battery.
Alarm transmitter Airborne DC Dual, AddSecure
Alarm transmitter IP/4G Neo
DSC
Alarm transmitter IP/4G Neo
Art. no.: 6310315
Integrated alarm transmitter TL280LE-EU for the NEO alarm systems for IP communication via Ethernet and 4G. High reliability as both 2G, 3G and 4G networks can be used. Can be used as primary or secondary alarm transmitter in the system. Full support for DLS remote programming. Handles SIA and Contact ID alarm formats and supports SMS functions and Connect Alarm App. TL280LE-EU handles image transmission to alarm center and App from Neo camera detectors. Mounted in the central unit's main enclosure with the accompanying mounting plate and easily connected with the connection cable. Antenna included. Can be programmed via the control panel or with the DLS5 program. Current consumption: 120mA min - 400mA max. Temperature range: -10 to +55 °C. SBSC approved in alarm class 3.
Alarm transmitter EasyLine 4G
ASC Global
Alarm transmitter EasyLine 4G
Art. no.: 6310391
Alarm transmitter EasyLine 4G with simulated telephone line and an input and an output. EasyLine GSM is a 4G transmitter that has a simulated telephone line that can be used to transmit alarms from central devices, alarm transmitters and other equipment via telephone line to alarm centers and dialing to mobile phones. There is also a transistor output that can be controlled via a phone call (output is activated when a recognized phone number is detected). Can be used to, for example, activate and deactivate an alarm system. 4G antenna included. The transmitter is perfect for replacing fixed telephone lines or when older 2 and 3G transmitters are to be upgraded to 4G. TIP/RING connection for PSTN line simulation. Transfer alarms from central devices and alarm transmitters directly to the alarm center via 4G voice (no programming required). Two-way voice communication. Decoding of Contact ID to send alarm to alarm center or as SMS (requires programming). One input (NO/NC). SMS, voice message can be sent to 8 phone numbers when activated on input. An output (monostable or bistable function). Output is activated when an unknown phone number is programmed (1000 phone numbers). PC program for programming with the possibility of firmware update. Enclosures in plastic and metal are available as accessories. As well as USB cable for programming. No programming is needed if only a simulated telephone line is desired, but if inputs and outputs are to be used, the transmitter must be programmed via a PC program Proread which can be downloaded here. Don't forget to order a programming cable.
Showing 16 of 16