Hager
Earth fault breaker 2-pole type A
RCCB 2P 25A 30MA A CDA225R
Article number: Suppl. article no:
2163652
CDA225R
to see price and stock
![Produkten är miljöbedömd av SundaHus Produkten är miljöbedömd av SundaHus](/globalassets/site-images/sv_icons/step/shc-.jpg)
![Produkten är bedömd hos Byggvarubedömningen med totalbedömningen Accepteras. Produkten är bedömd hos Byggvarubedömningen med totalbedömningen Accepteras.](/globalassets/site-images/sv_icons/step/accepteras.png)
![Denna produkt innehåller ett eller flera ämnen på kandidatförteckningen. Denna produkt innehåller ett eller flera ämnen på kandidatförteckningen.](/globalassets/site-images/sv_icons/step/reachinformationrequestobligation.png)
Earth fault breakers are used as personal or installation protection for conduction to earth that is greater than 10, 30 or 300 mA. All earth fault breakers are surge-proof, which means that they are protected against unnecessary disconnections from electric mains due to transients or what we call spikes. All earth fault breakers type A are DC pulse sensitive and can thus break the main circuit in the event of fault currents other than sinusoidal. A new DIN rail bracket with an advanced attachment mechanism means you can easily disconnect products from the DIN rail. A transparent protective cover for the marking areas on Hager’s new-generation modular components. To open and apply the marking strip, simply press the lower edge. The Semiolog marking program can be downloaded at Hager.se
- Article number: 2163652
- Suppl. article no: CDA225R
- Ean no: 3250611614432
- Material class QL2401
Technical data
- Packagin Size: 1 ST/60 ST/1440 ST
- Type: CDA225R
- Leakage current type: A
- Number of poles: 2
- Rated voltage: 230 V
- Voltage type: AC
- Rated current: 25 A
- Rated fault current: 0.03 A
- Built-in depth: 70 mm
- Width in number of modular spacings: 2
- Surge current capacity: 0.25 kA
- Selective protection: No
- Short-circuit breaking capacity (Icw): 6 kA
- Frequency: 50 Hz
- Short-time delayed tripping: No
- Degree of protection (IP): IP20
- Additional equipment possible: Yes
- Connectable conductor cross section solid-core: 1-25 mm²
- Connectable conductor cross section multi-wired: 1-16 mm²
- Mounting method: DIN rail
- Pollution degree: 2
- Rated impulse withstand voltage Uimp: 4 kV
- Rated insulation voltage Ui: 500 V
- Ambient temperature during operating: -25-40 °C
- With interlocking device: Yes
- REACH Date: 2022-11-23
- REACH contains candidate substances: Bly
- REACH Information obligation: Yes