Personal protection switch

Do you need fuses? Ahlsell helps you find installation material for all your electrical jobs. Whether you work with commercial properties or private residences, we have the range for your next project. We offer products from several well-known suppliers. Here you will find wall sockets, cable ladders, and accessories for easy installations. We also offer smart wall sockets, switches, and dimmers from several major suppliers. Modern products for modern solutions. All the installation material you need under one roof. A job well done begins with good materials. Explore our wide range of fuses, installation materials, and accessories here in the online store or visit your nearest Ahlsell shop.

Residual current circuit breaker 6kA typ A, characteristics B, Hager
Hager
Residual current circuit breaker 6kA typ A, characteristics B, Hager
Art. no.: 2163741
Personal protection machine type A, feature B with screw connection
A personal protection machine is earth fault protection with built-in over-current protection
found in a miniature circuit breaker, which saves space and gives the user easier overview.
The personal protection machine complies with standard EN 61009-1.
The supply conductor can be connected from the top or bottom side.
When a DIN rail component needs to be replaced, this can be done without affecting any other products but the current one.
The space-saving (2 modules) personal protection machine is used for personal and short-circuiting protection of 1-phase output groups.
The phase rail connection makes it possible to connect several personal protection machines to one and the same DIN rail
Residual current circuit breakers iDPN Vigi
Schneider Electric
Residual current circuit breakers iDPN Vigi
Art. no.: 2164985
iDPN Vigi, a combination of 1-pole miniature circuit breaker and earth fault protection with 2 modules’ width (36 mm), is of electromechanical type and works without external voltage sources. They are available in B- and C-curve in AC and A class as well as in Asi design, i.e. short-time delayed with elevated power surge resistance and breaking capacity 6kA or respectively 10kA. iDPN Vigi can be supplied with help functions for indication (help/signal contact) and remote tripping (shunt/undervoltage trigger), the same accessories as inC60 are used in addition to OF and SD, where A9A26924 (OF) and A9A26927 (SD) are to be used. Since the device has two connections with 9 mm space, there are special phase rails for this series (21505,21507,21093). Connections: tunnel connections up to 10 mm².
Residual current circuit breaker 6kA typ A, characteristics B, Quick Connect
Hager
Residual current circuit breaker 6kA typ A, characteristics B, Quick Connect
Art. no.: 2163614
Person protection machine type A, feature B with Quick Connect connection
A personal protection machine is earth fault protection with built-in over-current protection found in a
miniature circuit breaker, which saves space and gives the user easier overview.
QuickConnect: Fast and easy. The quick connect technology saves a lot of installation time for technicians compared to screws.
With "QuickConnect" it is possible to push the conductor (EK/FK) directly into the connection.
During installation of multi-stranded conductors (MC) and disassembly, press the button to open the connection, whereupon the conductor is simply pushed in/pulled out.
When a DIN rail component needs to be replaced, this can be done without affecting any other products but the current one.
With the spring-loaded quick connection you can rest assured that there is sufficient contact pressure and proper conductor connection without the use of screw joints. This means that previous inspection requirements and re-tightening of the connecting screws are no longer necessary.
Residual current circuit breaker 6kA typ A, characteristics B, Quick Connect
Residual current circuit breaker 6kA typ A, characteristics C, Quick Connect
Hager
Residual current circuit breaker 6kA typ A, characteristics C, Quick Connect
Art. no.: 2163634
Person protection machine type A, feature C with Quick Connect connection
A personal protection machine is earth fault protection with built-in over-current protection found in a
miniature circuit breaker, which saves space and gives the user easier overview.
QuickConnect: Fast and easy. The quick connect technology saves a lot of installation time for technicians compared to screws.
With "QuickConnect" it is possible to push the conductor (EK/FK) directly into the connection.
During installation of multi-stranded conductors (MC) and disassembly, press the button to open the connection, whereupon the conductor is simply pushed in/pulled out.
When a DIN rail component needs to be replaced, this can be done without affecting any other products but the current one.
With the spring-loaded quick connection you can rest assured that there is sufficient contact pressure and proper conductor connection without the use of screw joints. This means that previous inspection requirements and re-tightening of the connecting screws are no longer necessary.
Residual current circuit breaker 6kA typ A, characteristics C, Quick ConnectResidual current circuit breaker 6kA typ A, characteristics C, Quick Connect
Residual current circuit breaker 6kA typ A, characteristics C, Hager
Hager
Residual current circuit breaker 6kA typ A, characteristics C, Hager
Art. no.: 2163748
Personal protection machine type A, feature C with screw connection
A personal protection machine is earth fault protection with built-in over-current protection
found in a miniature circuit breaker, which saves space and gives the user easier overview.
The personal protection machine complies with standard EN 61009-1.
The supply conductor can be connected from the top or bottom side.
When a DIN rail component needs to be replaced, this can be done without affecting any other products but the current one.
The space-saving (2 modules) personal protection machine is used for personal and short-circuiting protection of 1-phase output groups.
The phase rail connection makes it possible to connect several personal protection machines to one and the same DIN rail.
Residual current circuit breaker 6kA typ A, characteristics C, HagerResidual current circuit breaker 6kA typ A, characteristics C, Hager
Residual current circuit breaker with overcurrent protection 4-pole type C, ADM, Hager
Hager
Residual current circuit breaker with overcurrent protection 4-pole type C, ADM, Hager
Art. no.: 2163665
An RCBO is an RCD with built-in over-current protection in an MCB, which saves space and makes things easier to see. An RCBO is an RCD with built-in over-current protection in an MCB. The RCBOs are of type A, for AC and pulsing DC residual current, and with the neutral on the right. Choose between B and C characteristics, 30 mA for protection against injury. Surge-proof, minimum temperature -25ºC and breaking capacity 6 kA
A new DIN rail bracket with an advanced attachment mechanism means you can easily disconnect products from the DIN rail.
A transparent protective cover for the marking areas on Hager’s new-generation modular components. To open and apply the marking strip, simply press the lower edge. The Semiolog marking program can be downloaded at Hager.se
RCDs with soft leads can be connected under the phase rail with screw connectors.
The phase rail is simply pressed into place; you need never re-tighten.
NOTE: Hager’s KDNxxx phase rail must be used.
Residual current circuit breaker with overcurrent protection 4-pole type C, ADM, HagerResidual current circuit breaker with overcurrent protection 4-pole type C, ADM, HagerResidual current circuit breaker with overcurrent protection 4-pole type C, ADM, HagerResidual current circuit breaker with overcurrent protection 4-pole type C, ADM, HagerResidual current circuit breaker with overcurrent protection 4-pole type C, ADM, Hager
Residual current circuit breaker with overcurrent protection Resi9 30mA 4-pole
Schneider Electric
Residual current circuit breaker with overcurrent protection Resi9 30mA 4-pole
Art. no.: 2165360
This Resi9 product is a standard mounted RCBO with short circuit and overcurrent protection (RCBO). It is a 3P+N switch with 3 protected poles, tripping curve C. The earth fault protection class is type A with a sensitivity of 30mA. The earth leakage protection time delay is instantaneous. Icn-rated short-circuit breaking capacity is up to 6000A in accordance with standard EN/IEC 61009-2-1. This product protects against short circuit, cable overload, electric shock through indirect contact and fire hazards. It provides a safe and reliable solution for commercial and industrial applications with high breaking capacity. This product complies with EN/IEC 61009-2-1 and EN/IEC 61009-1 standards. The electrical endurance is up to 7,500 cycles and the mechanical endurance is up to 20,000 cycles. This circuit breaker has contact position indicator and also has ON/OFF indication in the rocker. It has tunnel type cable connection at the top and bottom. The connection allows solid copper cables with a cross-sectional area between 1mm² and 16mm² as well as flexible copper cables with a cross-sectional area between 1mm² and 10mm². It is also possible to connect with terminal pins between 1mm² and 10mm². The Ue rated operating voltage is up to 400VAC with a working frequency of 50Hz. The Ui rated insulation voltage is up to 400V. Uimp's rated impulse withstand voltage is 4kV. The overvoltage category is 3. It is intended to be mounted on a DIN rail in a standard center. Dimensions are (W) 90mm x (H) 91mm x (D) 72.5mm. The product's color is white (RAL 9003) and the weight is 500g. The degree of pollution is 2. The tightening torque of the connection is 2N.m (top or bottom) with PZ2 screwdriver type. The stripping length is 13 mm (top or bottom). According to the IEC 60529 standard, the IP degree of protection is IP20 and IP40 mounted in a standard enclosure. The operating temperature is from -25°C to +40°C.
Residual current circuit breaker with overcurrent protection Resi9 30mA 4-poleResidual current circuit breaker with overcurrent protection Resi9 30mA 4-pole
Residual current circuit breaker with overcurrent protection Resi9 300mA 4-pole
Schneider Electric
Residual current circuit breaker with overcurrent protection Resi9 300mA 4-pole
Art. no.: 2165364
This Resi9 product is a standard mounted RCBO with short circuit and overcurrent protection (RCBO). It is a 3P+N switch with 3 protected poles, tripping curve C. The earth fault protection class is type A with a sensitivity of 300mA. The earth leakage protection time delay is instantaneous. Icn-rated short-circuit breaking capacity is up to 6000A in accordance with standard EN/IEC 61009-2-1. This product protects against short circuit, cable overload, electric shock through indirect contact and fire hazards. It provides a safe and reliable solution for commercial and industrial applications with high breaking capacity. This product complies with EN/IEC 61009-2-1 and EN/IEC 61009-1 standards. The electrical endurance is up to 7,500 cycles and the mechanical endurance is up to 20,000 cycles. This circuit breaker has contact position indicator and also has ON/OFF indication in the rocker. It has tunnel type cable connection at the top and bottom. The connection allows solid copper cables with a cross-sectional area between 1mm² and 16mm² as well as flexible copper cables with a cross-sectional area between 1mm² and 10mm². It is also possible to connect with terminal pins between 1mm² and 10mm². The Ue rated operating voltage is up to 400VAC with a working frequency of 50Hz. The Ui rated insulation voltage is up to 400V. Uimp's rated impulse withstand voltage is 4kV. The overvoltage category is 3. It is intended to be mounted on a DIN rail in a standard center. Dimensions are (W) 90mm x (H) 91mm x (D) 72.5mm. The product's color is white (RAL 9003) and the weight is 500g. The degree of pollution is 2. The tightening torque of the connection is 2N.m (top or bottom) with PZ2 screwdriver type. The stripping length is 13 mm (top or bottom). According to the IEC 60529 standard, the IP degree of protection is IP20 and IP40 mounted in a standard enclosure. The operating temperature is from -25°C to +40°C.
Showing 33 of 33