Feedback
Beulco
Jet Pump TVR, Beulco
JET 102 BEULCO BA38230 RING PUMP SELF-PRIMING
Article number: Suppl. article no:
5950657
0638230000
to see price and stock
Self-priming jet pump with associated ring pump adaptor kit for replacement of old 2- and 3-wheeled ring pumps. The pump is equipped with a three-phase motor which must be connected to appropriate motor protection. Monoblock type. With adjustable flanges for replacement of water ring pumps.
- Article number: 5950657
- Suppl. article no: 0638230000
- Ean no: 7331807055102
- Replaces art.nbr: 5950226
- Material class PHC100
Technical data
- Packagin Size: 1 ST/7 ST
- Nominal current: 1.9 A
- Insulation class according to IEC: F
- Nominal diameter connection inlet side: DN 25
- Number of phases: 3
- Motor power output (P2) per motor: 0.75 kW
- Electrical connection: Terminals
- Frequency: 50 Hz
- Degree of protection (IP): IP44
- Material pump casing: Cast iron
- Max. static height: 53 m
- Ambient temperature: 0-40 °C
- Type of drive: Electrical
- Forced motor cooling: No
- Connection inlet side: Internal thread cylindrical BSPP-G (ISO 228-1)
- Connection outlet side: Internal thread cylindrical BSPP-G (ISO 228-1)
- Nominal diameter connection outlet side: DN 25
- Flange shape: Oval
- Interface PT100 / PT1000 / PTC: No
- Interface Pulse Width Modulation (PWM): No
- Interface pulse counter: No
- Interface signal 0-10 V / 2-10 V: No
- Interface signal 0-20 mA / 4-20 mA: No
- Communication: None
- Cable length: 0 m
- Material impeller/pump wheel: Other
- Material quality impeller/pump wheel: Other
- Max. operating pressure: 8 bar
- Max. discharge flow: 3.6 m³/h
- With communication interface RS-232: No
- With communication interface RS-485: No
- Rated voltage: 230-400 V
- Volume flow rate (BEP): 3.6 m³/h
- Potential free switch contact: No
- Mobile communications standard 5G: No
- Radio standard WLAN 802.11: No
- Supporting protocol for BACnet IP: No
- Supporting protocol for BACnet MS/TP: No
- Supporting protocol for CAN/CANOpen: No
- Supporting protocol for EtherNet/IP: No
- Supporting protocol for KNX: No
- Supporting protocol for LIN Bus: No
- Supporting protocol for LON/LONWorks: No
- Supporting protocol for Modbus RTU: No
- Supporting protocol for Modbus TCP: No
- Supporting protocol for PROFINET IO: No
- Discharge head at flow rate (BEP): 530 kPa
- Radio standard Bluetooth: No
- Supporting protocol for PROFIBUS: No
- Outer pipe diameter connection inlet side: 25 mm
- Outer pipe diameter connection outlet side: 25 mm
- Mobile communications standard 2G (GSM): No
- Radio standard 3G: No
- Mobile communications standard 4G (LTE): No
- REACH Date: 2021-10-29
- REACH Information obligation: No