Feedback

Grundfos

Hot water circulation pump UP15-14B, Grundfos

UP15-14B PM 80 GRUNDFOS VVC 1x230V 50Hz
Article number: 
5803089
Suppl. article no: 
97916771





 to see price and stock
Wet, conventional.
  • Article number: 
    5803089
  • Suppl. article no: 
    97916771
  • Ean no: 
    5710626363766
  • Material class 
    PHH121
Technical data
  • Packagin Size: 1 ST/36 ST/360 ST/360 ST
  • Pump type: UP 15-14 B PM 80
  • Built-in length: 80 mm
  • Nominal diameter connection inlet side: Other
  • Nominal diameter connection outlet side: Other
  • Insulation class according to IEC: F
  • Degree of protection (IP): IP44
  • Frequency: 50/60 Hz
  • Motor speed control: None
  • Motor power input (P1) per motor: 0.007 kW
  • Nominal current: 0.07 A
  • Electrical connection: Connection cable with plug
  • Double pump: No
  • Pump circuit: Other
  • Rotational speed: 2900 Rpm
  • Connection inlet side: Internal thread cylindrical BSPP-G (ISO 228-1)
  • Connection outlet side: Internal thread cylindrical BSPP-G (ISO 228-1)
  • Material quality impeller/pump wheel: Other
  • Material impeller/pump wheel: Other
  • Connection standard inlet side: ISO 228-1
  • Connection standard outlet side: ISO 228-1
  • Number of phases: 1
  • Interface PT100 / PT1000 / PTC: No
  • Interface Pulse Width Modulation (PWM): No
  • Interface pulse counter: No
  • Interface signal 0-10 V / 2-10 V: No
  • Interface signal 0-20 mA / 4-20 mA: No
  • Communication: None
  • Material pump casing: Brass
  • Material quality pump casing: Zinc-poor bronze (Rg 10)
  • Max. operating pressure: 10 bar
  • Max. discharge flow: 0.41 m³/h
  • Max. static height: 1.4 m
  • With communication interface RS-232: No
  • With communication interface RS-485: No
  • Medium temperature (continuous): 2-95 °C
  • Rated voltage: 230 V
  • Volume flow rate (BEP): 0.41 m³/h
  • Ambient temperature: 0-95 °C
  • Potential free switch contact: No
  • Radio standard 5G: No
  • Radio standard WLAN 802.11: No
  • Supporting protocol for BACnet IP: No
  • Supporting protocol for BACnet MS/TP: No
  • Supporting protocol for CAN/CANOpen: No
  • Supporting protocol for EtherNet/IP: No
  • Supporting protocol for KNX: No
  • Supporting protocol for LIN Bus: No
  • Supporting protocol for LON/LONWorks: No
  • Supporting protocol for Modbus RTU: No
  • Supporting protocol for Modbus TCP: No
  • Supporting protocol for PROFINET IO: No
  • Discharge head at flow rate (BEP): 8.82 kPa
  • Flange compression stage connection inlet side: PN 10
  • Flange compression stage connection outlet side: PN 10
  • REACH Date: 2021-10-13
  • REACH Information obligation: No