Complete, highly efficient heat pump that provides heat, hot water, ventilation, and recovery. Includes an electrical boiler, heat pump, and maintenance-free water heater, and is intended for water-borne (low-temperature) radiator systems or floor heating systems.
With the ESC 40/41 accessory, the FIGHTER 370 can be installed in buildings requiring two different feed temperatures, e.g. where the building has both a radiator system and a floor heating system. Energy is recovered from the ventilation air, and then fed into the heating system and/or the water heater. Can be controlled and maintained via Internet/SMS.
With the ESC 40/41 accessory, the FIGHTER 370 can be installed in buildings requiring two different feed temperatures, e.g. where the building has both a radiator system and a floor heating system. Energy is recovered from the ventilation air, and then fed into the heating system and/or the water heater. Can be controlled and maintained via Internet/SMS.
- Article number: 6251247
- Suppl. article no: 066055
- Ean no: 7331421335376
- Replaces art.nbr: 6250010 6250108 6250671 6250988
- Material class PEQ140
Technical data
- Width: 600 mm
- Height: 2075 mm
- Device emplacement: Indoor positioning
- Depth: 616 mm
- Refrigerant pre-charge: 0.4 kg
- Weight: 202 kg
- Suitable for swimming pool water heating: No
- Suitable for active cooling: No
- Remote operation: Yes
- Type of refrigerant: R290
- Suitable for hot tap water: Yes
- Swimming pool controls: No
- Room temperature control: Yes
- Data transfer via internet: Yes
- Data transfer via USB: Yes
- Water heating energy efficiency class according to 811/2013/EU: A
- Type of regulation: Weather-dependent control
- Number of phases: 3
- Max. heating water supply temperature: 70 °C
- Hot tap water control integrated: Yes
- Frequency: 50 Hz
- Energy efficiency class space heating: A+
- Capacity profile: L
- Sound performance level according to EN 12102 at 0/35 °C: 44 dB(A)
- Suitable for additional heating central heating: Yes
- Cascadable: No
- Modulating compressor: No
- Heating capacity at 7/35 °C according to EN 14511: 2.18 kW
- ηwh (water heating energy efficiency): 75 %
- Data transfer via bus connection: No
- Air volume: 28-70 m³/h
- SEER low temperature application (35 °C) at colder conditions: 142 %
- SEER low temperature application (35 °C) at average conditions: 135 %
- SEER low temperature application (35 °C) at warmer conditions: 129 %
- SEER middle temperature application (55 °C) at colder conditions: 119 %
- SEER middle temperature application (55 °C) at average conditions: 114 %
- SEER middle temperature application (55 °C) at warmer conditions: 109 %
- Kind of optimization: Space sensor
- Type: F370