Feedback
- Article number: 6251441
- Suppl. article no: 064318
- Material class PEQ140
Technical data
- Weight outdoor unit: 83 kg
- Height outdoor unit: 895 mm
- Width outdoor unit: 1035 mm
- Depth outdoor unit: 422 mm
- Type of refrigerant: R32
- Model: Outdoor unit
- Suitable for swimming pool water heating: No
- Data transfer via internet: No
- Room temperature control: No
- Remote operation possible: No
- Suitable for hot tap water: Yes
- Suitable for additional heating central heating: Yes
- Type of regulation: On/Off
- Regulation for central heating boiler control: No
- External controller required: Yes
- Data transfer via USB: No
- With electric heating element: No
- COP at 7/35 °C according to EN 14511: 5.33
- Heating capacity at 7/35 °C according to EN 14511: 4 kW
- Regulation for buffer tank control: No
- Suitable for active cooling: Yes
- Swimming pool controls: No
- Kind of optimization: OpenTherm
- Connection voltage: 230 V
- Max. heating water supply temperature: 60 °C
- Fuse (slow): 16 A
- COPd at Tj = +7 °C: 5
- Sound pressure level outdoor unit according to EN 12102 at 0/35 °C /1m distance: 48 dB
- Nominal volume flow rate output system: 0.38 l/s
- External pressure system pump available at nominal flow: 6 bar
- Sound performance level outdoor unit according to EN 12102 at 0/35 °C: 53 dB(A)
- REACH Date: 2024-01-23
- REACH contains candidate substances: Bly
- Refrigerant pre-charge: 1.84 kg
- REACH Information obligation: Yes