Hager
Earth fault breaker 4-pole type A Quick Connect
RCCB 4P 25A 30MA A QC CDS425R
Article number: Suppl. article no:
2163820
CDS425R
to see price and stock
Earth fault breakers are used as personal or installation protection for conduction to earth that is greater than 10, 30 or 300 mA. All earth fault breakers are surge-proof, which means that they are protected against unnecessary disconnections from electric mains due to transients or what we call spikes. All earth fault breakers type A are DC pulse sensitive and can thus break the main circuit in the event of fault currents other than sinusoidal.
A new DIN rail bracket with an advanced attachment mechanism means you can easily disconnect products from the DIN rail. A transparent protective cover for the marking areas on Hager’s new-generation modular components. To open and apply the marking strip, simply press the lower edge. Semilog labelling program can be downloaded at hager.se. Earth fault breaker with soft leads can be connected under phase rail with screw connectors. The phase rail is simply pressed into place; you need never re-tighten. NOTE: Hager’s KDNxxx phase rail must be used.
A new DIN rail bracket with an advanced attachment mechanism means you can easily disconnect products from the DIN rail. A transparent protective cover for the marking areas on Hager’s new-generation modular components. To open and apply the marking strip, simply press the lower edge. Semilog labelling program can be downloaded at hager.se. Earth fault breaker with soft leads can be connected under phase rail with screw connectors. The phase rail is simply pressed into place; you need never re-tighten. NOTE: Hager’s KDNxxx phase rail must be used.
- Article number: 2163820
- Suppl. article no: CDS425R
- Ean no: 3250611611158
- Material class QL2602
Technical data
- Packagin Size: 1 PCS/36 PCS/864 PCS
- Type: CDS425R
- Leakage current type: A
- Number of poles: 4
- Rated voltage: 400 V
- Voltage type: AC
- Rated current: 25 A
- Rated fault current: 0.03 A
- Built-in depth: 70 mm
- Width in number of modular spacings: 4
- Surge current capacity: 0.25 kA
- Selective protection: No
- Short-circuit breaking capacity (Icw): 6 kA
- Frequency: 50 Hz
- Short-time delayed tripping: No
- Degree of protection (IP): IP20
- Additional equipment possible: Yes
- Connectable conductor cross section solid-core: 1-25 mm²
- Connectable conductor cross section multi-wired: 1-16 mm²
- Mounting method: DIN rail
- Pollution degree: 2
- Rated impulse withstand voltage Uimp: 4 kV
- Rated insulation voltage Ui: 500 V
- Ambient temperature during operating: -25-40 °C
- With interlocking device: No
- REACH Date: 2022-11-23
- REACH contains candidate substances: Bly
- REACH Information obligation: Yes