Feedback

Nexans
GAHSQ-K-DHNRV indoor/outdoor strip G652D S12 Dca, Nexans
GAHSQ 12/C4 G652D S12 (SLIM) 29481598-805-00
Article number: Suppl. article no:
4700940
29481598-805-00
to see price and stock



Fiber optic cable of the type GAHSQ (formerly called GASQBDUV) is a track cable with ribbon fiber. The cable is intended for use in local area networks, area networks and property area networks. GAHSQ is also used as a stub cable in pre-terminated fiber optic cross-connect boxes. Fiber optic ribbon cable for indoor or outdoor installation in ducts. The cable is available from 4 to 1000 fibers. The fibers are joined in 4- or 8-fiber strips. 4 fiber ribbons are available in cable with between 4 and 96 fibers. 8-fiber tapes are available in cables from 144 to 1000 fibers (48 and 96 fiber cables are available with 8-fiber tapes). The straps are placed in a groove core of polyethylene with a central strain relief of fiberglass-reinforced plastic (FRP). GAHSQ is longitudinally waterproof through swelling bands. The cable sheath is made of halogen-free flame-retardant material and meets fire class according to CPR Dcas2d2a2. In case of fire, the cable emits no corrosive gases and has little smoke generation.
- Article number: 4700940
- Suppl. article no: 29481598-805-00
- Ean no: 7330000139213
- Material class QR1521
Technical data
- Number of fibres: 12
- Number of fibres per tube: 0
- Outer diameter approximate: 6.3 mm
- Colour outer sheath: Green
- Fibre type: Single mode 9/125
- Category: OS2
- Blow in: Yes
- Reaction-to-fire according to EN 13501-6: Flaming droplets/particles: d2
- Reaction-to-fire according to EN 13501-6: Smoke production: s2
- Reaction-to-fire according to EN 13501-6: Class: Dca
- Specification material outer sheath: Polyethylene (PE)
- Type of tube: Loose tube
- Material outer sheath: Polyolefin
- Suitable for underground installation: Yes
- Min. permitted bending radius, stationary application/permanent installation: 63 mm
- With strain relief: Yes
- Cable metal free: Yes
- Longitudinal water blocking cable: Yes
- Radial water blocking cable: No
- With rodent protection: No
- Oil resistant according to EN IEC 60811-404: Yes
- Reaction-to-fire according to EN 13501-6: Acidity: a2
- UV resistant: Yes
- Resistant to chemicals: Yes
- Cable geometry: Round
- Max. tensile strength during installation: 0.4 kN
- Weight: 37 kg/km
- Fibre standard: G652D
- Fibre optic cable colour coding according to S-12 Skanova standard: Yes
- Circuit integrity: None
- Flame retardant according to IEC 60332-1-2: Yes
- Halogen free according to EN IEC 60754-2: Yes
- REACH Date: 2023-10-16
- REACH contains candidate substances: 1-Propanone, 2-methyl-1-[(4-methylthio)phenyl]-2-(4-morpholinyl)- | diphenyl(2,4,6-trimethylbenzoyl)phosphine oxide
- Armouring: No
- REACH Information obligation: Yes
- Halogen free according to EN 60754-1/2: Yes
- Flame retardant: According to IEC/EN 60332-1-2
- Low smoke (according to EN 61034-2): Yes