Feedback

Tele/signal cable ELLY 4x0.6, Hexatronic - ELLY 4X0,6 BLACK (*7)   A9521689/02
Hexatronic

Tele/signal cable ELLY 4x0.6, Hexatronic

ELLY 4X0,6 BLACK (*7) A9521689/02
Article number: 
4808600
Suppl. article no: 
TEL3100706/4





 to see price and stock
Intended as a subscriber cable in distribution networks for telephony and digital telecommunications XDSL. Polyethylene insulated, four-screw twisted and polyethylene sheathed cable. Placement outdoors in ducts or directly in the ground according to S 424 14 37. Indoors max. 5 m for termination in terminal block or joint.
  • Article number: 
    4808600
  • Suppl. article no: 
    TEL3100706/4
  • Ean no: 
    7333106001248
  • Material class 
    QR0400
Technical data
  • Dimension conductor x diameter: 4x0,6 mm
  • Diameter conductor: 0.6 mm
  • Outer diameter approximate: 6.5 mm
  • Colour outer sheath: Black
  • Halogen free according to EN IEC 60754-2: Yes
  • Reaction-to-fire according to EN 13501-6: Class: None
  • Specification material outer sheath: Polyethylene (PE)
  • Longitudinal water blocking cable: No
  • Radial water blocking cable: Yes
  • Screen over stranding element: None
  • Screen over stranding: None
  • Conductor category: Class 1 = solid
  • Material outer sheath: Polyolefin
  • Core identification: Colour
  • Stranding element: Quad
  • Material core insulation: Polyolefin
  • Stranding: Layers
  • Permitted cable outer temperature after assembling without vibration: -40-70 °C
  • Permitted cable outer temperature during assembling/handling: -15-50 °C
  • Number of cores: 4
  • Number of stranding elements: 1
  • Reaction-to-fire according to EN 13501-6: Flaming droplets/particles: None
  • Category: 3
  • Nominal cross section conductor: 0.28 mm²
  • Conductor surface: Bare
  • Suitable for underground installation: Yes
  • Min. permitted bending radius, stationary application/permanent installation: 30 mm
  • Oil resistant according to EN IEC 60811-404: No
  • Low smoke according to EN IEC 61034-2: Yes
  • Reaction-to-fire according to EN 13501-6: Smoke production: None
  • Specification core insulation: Polyethylene (PE)
  • Reaction-to-fire according to EN 13501-6: Acidity: None
  • UV resistant: Yes
  • REACH Date: 2021-09-03
  • REACH Information obligation: No
  • Halogen free according to EN 60754-1/2: Yes
  • Flame retardant: No
  • Insulation integrity according to IEC 60331: No
  • Oil resistant (according to IEC 60811-404): No
  • Low smoke (according to EN 61034-2): Yes