Alarm/signal cable halogen-free ELAQBY red Dcas2d2a2, Nexans
ELAQBY 2X2X0.6 RED R100 18456040-803-02
Article number: Suppl. article no:
4802212
18456040-803-02
to see price and stock
Twisted pair, shielded, telecommunication and signal cable with halogen-free, flame-retardant sheath. The screen consists of an elongated aluminum foil and a connecting wire of tinned copper. The aluminum foil is glued to the jacket and forms a so-called moisture barrier jacket. The cable is laid indoors in a permanent installation and protected against mechanical damage also outdoors and in the ground. Meets fire requirements according to CPR class Dcas2d2a2. In case of fire, the cable emits no corrosive gases and has little smoke evolution.
- Article number: 4802212
- Suppl. article no: 18456040-803-02
- Ean no: 7330000140455
- Material class QR0650
Technical data
- Packagin Size: 100 M
- Cable type: ELAQBY
- Dimension conductor x diameter: 2x2x0,6 mm
- Diameter conductor: 0.6 mm
- Cable geometry: Round
- Outer diameter approx.: 7 mm
- Colour outer sheath: Red
- Halogen free according to EN IEC 60754-2: Yes
- Reaction-to-fire according to EN 13501-6: Class: Dca
- Conductor material: Copper
- Specification material outer sheath: Polyethylene (PE)
- Armouring/reinforcement: None
- Longitudinal water blocking cable: No
- Radial water blocking cable: Yes
- Screen over stranding element: None
- Screen over stranding: Foil
- Conductor category: Class 1 = solid
- Material outer sheath: Polyolefin
- Core identification: Colour
- Protective sheath: Al/PE
- Stranding element: Other
- Material core insulation: Other
- Stranding: Bundle
- Permitted cable outer temperature after assembling without vibration: -40-70 °C
- Permitted cable outer temperature during assembling/handling: -10-50 °C
- Number of cores: 4
- Number of stranding elements: 2
- Reaction-to-fire according to EN 13501-6: Flaming droplets/particles: d2
- Nominal cross section conductor: 0.28 mm²
- Conductor surface: Bare
- Suitable for underground installation: Yes
- Min. permitted bending radius, stationary application/permanent installation: 70 mm
- Oil resistant according to EN IEC 60811-404: No
- Low smoke according to EN IEC 61034-2: Yes
- Reaction-to-fire according to EN 13501-6: Smoke production: s2
- Specification core insulation: Polyethylene (PE)
- Reaction-to-fire according to EN 13501-6: Acidity: a2
- UV resistant: No
- Suitable as signalling cable: Yes
- Approved type of underground installation: Underground installation tube
- Weight: 70 kg/km
- Number of sheath layers: 1
- Drain wire: Yes
- Circuit integrity: None
- With rodent protection: Yes
- Nominal voltage U: 100 V
- REACH Date: 2021-06-14
- GWP-tot (A1-A3): 0,3238 kgCO2e/M
- REACH Information obligation: No