Feedback
AhlsellProductsElectricCable 00-05, 48-4901 Control cable, single core and strandedControl cable halogen-free
NKT
Control cable halogen-free FQAR-PG 150/250 V, Nkt
FQAR-PG 2X2X0.5 (*5)
Article number:
0173910
to see price and stock
Halogen-free cable that in case of fire gives off a smoke that is free from corrosive gases and has a low density. For fixed installations indoors and outdoors, open and in pipes and ducts. For signalling where high demands on immunity from disturbances and protection against overheating.
Stranded, tempered tinned copper according to IEC 60228, class 2, SS4241475 (F3). Halogen-free numbered insulation. Parties twined in pairs before cabling and bound with PET foil.
Screen: Plastic laminated aluminium foil with bi-conductor.
Sleeve marking, example: “nkt cables FQAR-PG 4x2x0,5 150/250 V"
Certificates: Standard SS 424 03 21, HD 627 Part 4 C2 itd
Operating temperature: Maximum 70°C during continuous operation.
Stranded, tempered tinned copper according to IEC 60228, class 2, SS4241475 (F3). Halogen-free numbered insulation. Parties twined in pairs before cabling and bound with PET foil.
Screen: Plastic laminated aluminium foil with bi-conductor.
Sleeve marking, example: “nkt cables FQAR-PG 4x2x0,5 150/250 V"
Certificates: Standard SS 424 03 21, HD 627 Part 4 C2 itd
Operating temperature: Maximum 70°C during continuous operation.
- Article number: 0173910
- Material class QA3100
Technical data
- Cable type: FQAR-PG
- Dimension conductor x area: 2x2x0,5 mm²
- Number of cores: 4
- Nominal cross section conductor: 0.5 mm²
- With protective conductor: No
- Screen over stranding element: None
- Screen over stranding: Foil
- Outer diameter approx.: 7 mm
- Weight/100 m: 7.3 kg
- Conductor category: Class 2 = stranded
- Colour outer sheath: Grey
- Material outer sheath: Polyolefin
- Material core insulation: Polyolefin
- Nominal voltage U: 250 V
- Core identification: Numbers
- Stranding element: Pairs
- REACH Date: 2021-12-09
- Low smoke (according to EN 61034-2): Yes
- Halogen free according to EN 60754-1/2: Yes
- Flame retardant: According to IEC/EN 60332-1-2
- REACH Information obligation: No