AhlsellProductsElectricCable 00-05, 48-4900 Power cableFire-resistance power cable, halogen-free version

Nexans
Ground cable fireproof Alsecure Plus 1kV
ALSECURE PLUS 4X6/6 1KV (*0)
Article number: Suppl. article no:
0055450
35123980900
to see price and stock


The cable is intended for fixed installation both indoors and outdoors in all types of spaces where there are requirements for function during and after a fire in, for example, emergency lighting, fire alarm systems and control systems. The cable can also be laid directly in the ground. Alsecure Plus is a halogen-free, flame-retardant power cable with round or sector-shaped, few-stranded, annealed copper conductors. The cable is insulated with Mica tape + colored PEX and a screen of copper wires with counter-helix. The cable is constructed according to SS 424 14 18. The conductors have a wire count and resistance according to IEC 60228 class 2. The parts are color-coded according to SS 424 17 20. The sheath is marked with type/manufacturer/year+month/meter marking, color orange. Alsecure Plus meets fire spread class IEC 60332-3 category C (F4C) and does not emit any corrosive gases in the event of a fire and has little smoke development. The cable is approved by SEMKO. LifemarkTM recycling marking: Permanent marking on the cable's outer sheath. The marking specifies the plastic grades used and prepares the cable for recycling.
- Article number: 0055450
- Suppl. article no: 35123980900
- Ean no: 7330000073050
- Material class QA0100
Technical data
- Cable type: Alsecure Plus
- Number of cores: 5
- Nominal cross section conductor: 6 mm²
- Dimension conductor x area: 4x6/6 mm²
- Outer diameter approx.: 18 mm
- Colour outer sheath: Orange
- Weight: 537 kg/km
- Weight/100 m: 55 kg
- Nominal voltage U: 1 kV
- Nominal voltage U0: 0.6 kV
- Halogen free according to EN IEC 60754-2: Yes
- Reaction-to-fire according to EN 13501-6: Class: None
- Reaction-to-fire according to EN 13501-6: Smoke production: None
- Reaction-to-fire according to EN 13501-6: Flaming droplets/particles: None
- Reaction-to-fire according to EN 13501-6: Acidity: None
- Conductor material: Copper
- Conductor category: Class 2 = stranded
- Shape of conductor: Round
- Screen: Yes
- Drain wire: No
- Lead sheath: No
- Permitted cable outer temperature after assembling without vibration: -40-70 °C
- Permitted cable outer temperature during assembling/handling: -10-50 °C
- Concentric conductor: Copper
- Material outer sheath: Polyolefin
- Nominal cross section concentric conductor: 6 mm²
- Core identification: Colour
- With protective conductor: Yes
- Material core insulation: Other
- Max. permitted conductor temperature: 90 °C
- Fibre optic elements: No
- Inner semi-conducting layer: No
- Laminated sheath: No
- Conductive coating: No
- Conductor surface: Bare
- Longitudinal water blocking screen: No
- Longitudinal water blocking conductors: No
- Low smoke according to EN IEC 61034-2: Yes
- Outer semi-conducting layer: No
- Certified for shipboard application: No
- Certified as airport lighting cable: No
- Cable geometry: Round
- Min. permitted bending radius, stationary application/permanent installation: 144 mm
- Core identification according to HD 308 S2: Yes
- Conductor resistance at 20 °C: 3.08 Ohm/km
- Specification core insulation: Crosslinked polyethylene (XLPE)
- Circuit integrity: E90
- REACH Date: 2021-06-14
- REACH Information obligation: No
- Low smoke (according to EN 61034-2): Yes