Loe voltage FXQJ EMC kV Dca, Nexans - FXQJ EMC 4X25/16 1KV BL (*5)
Nexans

Loe voltage FXQJ EMC kV Dca, Nexans

FXQJ EMC 4X25/16 1KV BL (*5)
Article number: 
0054180
Suppl. article no: 
15143698-201-00





 to see price and stock
Produkten är miljöbedömd av SundaHusProdukten är bedömd hos Byggvarubedömningen med totalbedömningen Accepteras.
The cable is intended for fixed installation indoors and outdoors in air, soil and water and is suitable for industrial installations and other installations that have EMC requirements. FXQJ is a halogen-free, PEX-insulated and HFFR-coated cable with round copper wires of copper for areas up to 35 mm2. Other areas have few sector-shaped copper conductors. FXQJ is constructed in accordance with SS 424 14 18 The cable has a shield of annealed copper wire with counter-coil of solid copper strip. The conductors have thread count and resistance according to IEC 60228 class 2. The parties are color marked according to SS 424 17 20. The cable has a sprayed filling. The mantle is labeled type / manufacturer / year + month / meter marking. FXQJ meets fire spread class D. The cable is approved by SEMKO. The cable is marked with Lifemark TM recycling mark (content declared).
  • Article number: 
    0054180
  • Suppl. article no: 
    15143698-201-00
  • Ean no: 
    7330000077003
  • Replaces art.nbr: 
    0013180
  • Material class 
    QA0200
Technical data
  • Cable type: FXQJ EMC
  • Number of cores: 5
  • Nominal cross section conductor: 25 mm²
  • Dimension conductor x area: 4x25/16 mm²
  • Outer diameter approximate: 27 mm
  • Colour outer sheath: Black
  • Weight: 1550 kg/km
  • Weight/100 m: 154 kg
  • Nominal voltage U: 1 kV
  • Nominal voltage U0: 0.6 kV
  • Halogen free according to EN IEC 60754-2: Yes
  • Reaction-to-fire according to EN 13501-6: Class: Dca
  • Reaction-to-fire according to EN 13501-6: Smoke production: s2
  • Reaction-to-fire according to EN 13501-6: Flaming droplets/particles: d2
  • Reaction-to-fire according to EN 13501-6: Acidity: a2
  • Conductor material: Copper
  • Conductor category: Class 2 = stranded
  • Shape of conductor: Round
  • Screen: Yes
  • Drain wire: No
  • Lead sheath: No
  • Permitted cable outer temperature after assembling without vibration: -40-70 °C
  • Permitted cable outer temperature during assembling/handling: -10-50 °C
  • Concentric conductor: Copper
  • Material outer sheath: Polyolefin
  • Nominal cross section concentric conductor: 16 mm²
  • Core identification: Colour
  • With protective conductor: Yes
  • Material core insulation: Other
  • Max. permitted conductor temperature: 90 °C
  • Fibre optic elements: No
  • Inner semi-conducting layer: No
  • Laminated sheath: No
  • Conductive coating: No
  • Conductor surface: Bare
  • Longitudinal water blocking screen: No
  • Longitudinal water blocking conductors: No
  • Low smoke according to EN IEC 61034-2: Yes
  • Outer semi-conducting layer: No
  • Certified for shipboard application: No
  • Certified as airport lighting cable: No
  • Cable geometry: Round
  • Suitable as installation cable: Yes
  • Min. permitted bending radius, stationary application/permanent installation: 216 mm
  • Core identification according to HD 308 S2: Yes
  • Conductor resistance at 20 °C: 0.727 Ohm/km
  • Specification core insulation: Crosslinked polyethylene (XLPE)
  • Radial water blocking cable: No
  • Suitable for underground installation: Yes
  • Max. tensile strength during installation: 5 kN
  • Oil resistant according to EN IEC 60811-404: Yes
  • UV resistant: Yes
  • REACH Date: 2021-06-14
  • GWP-tot (A1-A3): 3,4224 kgCO2e/M
  • Armouring: No
  • REACH Information obligation: No
  • Halogen free according to EN 60754-1: Yes
  • Halogen free according to EN 60754-1/2: Yes
  • Halogen free according to EN 60754-2: Yes
  • Insulation integrity according to IEC 60331: No
  • Oil resistant (according to IEC 60811-404): Yes
  • Low smoke (according to EN 61034-2): Yes
  • Halogen free according to EN 60754-3: Yes