Feedback

Low voltage EXQJ 1kV Dca, Nkt - EXQJ 3X10/10 (*5)
NKT

Low voltage EXQJ 1kV Dca, Nkt

EXQJ 3X10/10 (*5)
Article number: 
0017240





 to see price and stock
Use: Halogen-free cable that gives off smoke with low smoke density and free from corrosive gases in the event of fire. 4-conductor with full screen area for use in 5-conductor systems. Open fixed place, indoors and outdoors, in pipes, in soil and in water.
Conductor temperature: Max. 90 ° C, Short-circuit temperature: Max. 250 ° C, Placement temperature: Min. 0 ° C, Bending radius: Min. 10 x D, Tensile force: 50 N / mm² when connected directly in all conductors, however max. 20,000 N. Conductor: Round filamentous annealed copper, Insulation: PEX, Part marking: 3-conductor: Brown, black, gray 4-conductor: Blue, brown, black, gray, Filler jacket: Sprayed, halogen-free, Concentric conductor: Annealed copper wire with counter-coil , Sheath: Halogen-free compound, Sheath color: Black, Standard: SS 424 14 18 where applicable, Rated voltage: 1 kV, Test voltage: 3.5 kV, Fire rating: D, CE conformity: Low voltage directive.
  • Article number: 
    0017240
  • Ean no: 
    7394479012187
  • Material class 
    QA070A
Technical data
  • Cable type: EXQJ
  • Number of cores: 3
  • Nominal cross section conductor: 10 mm²
  • Dimension conductor x area: 3x10/10 mm²
  • Outer diameter approximate: 17 mm
  • Colour outer sheath: Black
  • Weight/100 m: 66 kg
  • Nominal voltage U: 1 kV
  • Nominal voltage U0: 0.6 kV
  • Halogen free according to EN IEC 60754-2: Yes
  • Reaction-to-fire according to EN 13501-6: Class: Dca
  • Reaction-to-fire according to EN 13501-6: Smoke production: s2
  • Reaction-to-fire according to EN 13501-6: Flaming droplets/particles: d2
  • Reaction-to-fire according to EN 13501-6: Acidity: a2
  • Conductor material: Copper
  • Conductor category: Class 1 = solid
  • Shape of conductor: Round
  • Number of pilot/reduced conductors: 0
  • Screen: Yes
  • Drain wire: No
  • Lead sheath: No
  • Concentric conductor: Copper
  • Material outer sheath: Polyolefin
  • Nominal cross section concentric conductor: 10 mm²
  • Core identification: Colour
  • With protective conductor: No
  • Material core insulation: Other
  • Max. permitted conductor temperature: 90 °C
  • Fibre optic elements: No
  • Inner semi-conducting layer: No
  • Laminated sheath: No
  • Conductive coating: No
  • Conductor surface: Bare
  • Longitudinal water blocking screen: No
  • Longitudinal water blocking conductors: No
  • Low smoke according to EN IEC 61034-2: Yes
  • Outer semi-conducting layer: No
  • Cable geometry: Round
  • Specification core insulation: Crosslinked polyethylene (XLPE)
  • REACH Date: 2021-12-09
  • Armouring: No
  • REACH Information obligation: No
  • Flame retardant: According to IEC/EN 60332-3-24
  • Low smoke (according to EN 61034-2): Yes
  • Insulation integrity: None