Feedback

NKT
Ground cable RXQ 1kV Dca, NKT
RXQ Xtra 3G1,5 Dca
Article number: Suppl. article no:
0017100
112700008
to see price and stock

Multi-core halogen-free unshielded 1kV cable. Tearing wire for easier and safer peeling. Sheath that can be easily broken off after instructions are made with a knife. Soft and thin for quick and easy installation. Cables according to this standard are intended for open fixed installation as well as in pipes. The cables can be laid indoors and outdoors as well as in the ground, but not in potentially explosive rooms. Insulation: PEX, UV stabilized according to SS-EN ISO 4892-3:2016.
- Article number: 0017100
- Suppl. article no: 112700008
- Ean no: 7394479022278
- Material class QA0500
- This is an alternative to item 0017000
Technical data
- Packagin Size: 1 M/500 M
- Cable type: RXQ
- Dimension conductor x area: 3G1,5 mm²
- Colour outer sheath: Black
- Outer diameter approximate: 10.84 mm
- Screen: No
- Reaction-to-fire according to EN 13501-6: Class: Dca
- Permitted cable outer temperature during assembling/handling: -20-70 °C
- Permitted cable outer temperature after assembling without vibration: -40-70 °C
- Conductor category: Class 5 = flexible
- Nominal voltage U0: 1000 V
- Oil resistant according to EN IEC 60811-404: No
- Nominal voltage U: 1000 V
- Material core insulation: Polyolefin
- Nominal cross section conductor: 1.5 mm²
- Number of cores: 3
- Armouring/reinforcement: None
- Drain wire: No
- Reaction-to-fire according to EN 13501-6: Flaming droplets/particles: d2
- Conductor material: Copper
- Conductor surface: Bare
- Material outer sheath: Polyolefin
- Max. permitted conductor temperature: 90 °C
- Min. permitted bending radius, stationary application/permanent installation: 87 mm
- Core identification: Colour
- Reaction-to-fire according to EN 13501-6: Smoke production: s2
- Protective barrier: None
- With protective conductor: No
- Specification core insulation: Crosslinked polyethylene (XLPE)
- Specification material outer sheath: Other
- Reaction-to-fire according to EN 13501-6: Acidity: a2
- Certified for shipboard application: No
- Certified as airport lighting cable: No
- Cable geometry: Round
- Shape of conductor: Round
- Conductor resistance at 20 °C: 13.3 Ohm/km
- Suitable as installation cable: No
- Core identification according to HD 308 S2: Yes
- Weight: 170 kg/km
- Lead sheath: No
- Halogen free according to EN IEC 60754-2: Yes
- Low smoke according to EN IEC 61034-2: Yes
- REACH Date: 2023-05-15
- REACH Information obligation: No