Low voltage EXQ Infra 1kV Eca, Nexans

EXQ INFRA 4G10 1KV BLACK (*5)
Article number: 
0013710
Suppl. article no: 
15026098-201-00





 to see price and stock
Produkten är miljöbedömd av SundaHusProdukten är bedömd hos Byggvarubedömningen med totalbedömningen Accepteras.
The cable is intended for fixed installation indoors and outdoors in air, ground and water. EXQ INFRA is a halogen-free, PEX-insulated, HFFR-coated cable with solid copper conductors. The cable is constructed in accordance with SS 424 14 18. The conductors have resistance according to IEC 60228 class 1. The parties are color-labeled according to SS 424 17 20. The cable has filler. The mantle is labeled type / manufacturer / year + month / meter marking. The cable's sheath is made of halogen-free flame-retardant material and meets the fire class according to CPR class E. In case of fire, the cable does not emit corrosive gases and has a small smoke emission. EXQ INFRA is manufactured and tested according to SS 424 14 18. The cable can be loaded according to SS 424 14 24. Lifemark: Permanent marking on the outer casing of the cable. The marking specifies in-depth plastic qualities and prepares for future recycling of the cable. EXQ INFRA replaces SE-N1XV-U.
  • Article number: 
    0013710
  • Suppl. article no: 
    15026098-201-00
  • Ean no: 
    7330000115071
  • Replaces art.nbr: 
    0012010
  • Material class 
    QA1000
Technical data
  • Cable type: EXQ INFRA
  • Nominal cross section conductor: 10 mm²
  • Number of cores: 4
  • Dimension conductor x area: 4G10 mm²
  • Outer diameter approx.: 17.5 mm
  • Colour outer sheath: Black
  • Weight: 540 kg/km
  • Weight/100 m: 54 kg
  • With protective conductor: No
  • Conductor material: Copper
  • Number of pilot/reduced conductors: 0
  • Core identification: Colour
  • Conductor category: Class 1 = solid
  • Nominal voltage U: 1 kV
  • Nominal voltage U0: 0.6 kV
  • Max. conductor temperature: 90 °C
  • Drain wire: No
  • Screen: No
  • Lead sheath: No
  • Reaction-to-fire according to EN 13501-6: Class: Eca
  • Reaction-to-fire according to EN 13501-6: Flaming droplets/particles: None
  • Reaction-to-fire according to EN 13501-6: Smoke production: None
  • Reaction-to-fire according to EN 13501-6: Acidity: None
  • Fibre optic elements: No
  • Halogen free according to EN IEC 60754-2: Yes
  • Inner semi-conducting layer: No
  • Concentric conductor: None
  • Laminated sheath: No
  • Conductive coating: No
  • Shape of conductor: Round
  • Conductor surface: Bare
  • Longitudinal water blocking conductors: Yes
  • Material outer sheath: Polyolefin
  • Low smoke according to EN IEC 61034-2: Yes
  • Outer semi-conducting layer: No
  • Min. permitted bending radius, stationary application/permanent installation: 140 mm
  • Specification core insulation: Crosslinked polyethylene (XLPE)
  • Cable geometry: Round
  • Conductor resistance at 20 °C: 1.83 Ohm/km
  • Circuit integrity: None
  • REACH Date: 2021-06-14
  • Armouring: No
  • REACH Information obligation: No
  • Halogen free according to EN 60754-1/2: Yes
  • Flame retardant: According to IEC/EN 60332-1-2
  • Insulation integrity according to IEC 60331: No
  • Oil resistant (according to IEC 60811-404): Yes
  • Low smoke (according to EN 61034-2): Yes
  • Insulation integrity: None