Feedback
Siemens
Base system S7-1500 modular
CPU 1517F-3 PN/DP. 3MB PROG.. 6ES7517-3FP00-0AB0
Article number: Suppl. article no:
4500137
6ES7517-3FP00-0AB0
to see price and stock
All CPUs have a corresponding Safety CPU, F-CPU. All CPUs have a built-in PROFINET interface (2-port switch). CPU 1516, 1517 and 1518 also have an interface for ethernet (PROFINET basic), e.g. to connect to a parent network, and the PROFIBUS interface (only the master, for the slave and expand your module is necessary). All CPUs are equipped with a display. One must specially order a SIMATIC memory card to all CPUs.
- Article number: 4500137
- Suppl. article no: 6ES7517-3FP00-0AB0
- Ean no: 4047623403944
- Material class QP810A
Technical data
- Type: 6ES7517-3FP00-0AB0
- Design: CPU 1517F-3 PN/DP
- Number of interfaces PROFINET: 2
- Number of HW-interfaces wireless: 0
- Number of analogue inputs: 0
- Number of analogue outputs: 0
- Number of digital inputs: 0
- Number of digital outputs: 0
- Number of HW-interfaces RS-232: 0
- Number of HW-interfaces RS-422: 0
- Number of HW-interfaces RS-485: 1
- Number of HW-interfaces USB: 0
- Number of HW-interfaces other: 0
- Number of HW-interfaces industrial Ethernet: 2
- Number of HW-interfaces parallel: 0
- Width: 175 mm
- Depth: 129 mm
- Explosion safety category for gas: ATEX gas-ex-protection, Cat. 3G
- Explosion safety category for dust: None
- Additional program memory possible: No
- Suitable for safety functions: Yes
- Supply voltage DC: 19.2-28.8 V
- Height: 147 mm
- IO link master: No
- Supporting protocol for LON: No
- Number of relay outputs: 0
- With display: Yes
- Memory size: 11000 kByte
- Model: Modular
- With optical interface: No
- Front built-in possible: No
- Processing time (1K, binary operation): 0.002 ms
- Rack-assembly possible: No
- Radio standard WLAN 802.11: No
- Redundancy: No
- Suitable for rail mounting: Yes
- Radio standard GPRS: No
- Radio standard GSM: No
- Radio standard UMTS: No
- Supporting protocol for ASI: No
- Supporting protocol for CAN: No
- Supporting protocol for Data-Highway: No
- Supporting protocol for DeviceNet: No
- Supporting protocol for KNX: No
- Supporting protocol for INTERBUS-Safety: No
- Supporting protocol for INTERBUS: No
- Supporting protocol for Modbus: Yes
- Supporting protocol for SERCOS: No
- Supporting protocol for SUCONET: No
- Supporting protocol for TCP/IP: Yes
- Supporting protocol for other bus systems: No
- Supporting protocol for AS-Interface Safety at Work: No
- Supporting protocol for DeviceNet Safety: No
- Supporting protocol for EtherNet/IP: No
- Supporting protocol for Foundation Fieldbus: No
- Supporting protocol for PROFINET CBA: No
- Supporting protocol for PROFINET IO: Yes
- Supporting protocol for PROFIsafe: Yes
- Supporting protocol for SafetyBUS p: No
- System accessory: Yes
- Appendant operation agent (Ex ia): No
- Appendant operation agent (Ex ib): No
- Voltage type (supply voltage): DC
- Type of memory: Other
- Wall mounting/direct mounting: No
- Radio standard Bluetooth: No
- Supporting protocol for PROFIBUS: Yes
- REACH Date: 2022-03-14
- REACH contains candidate substances: Bisfenol A synonym difenylolpropan eller 4,4'-Isopropylidendifenol, Bisphenol A | Bly | Lead oxide, Blyoxid, Blymonoxid, C.I. Pigment Yellow 46 , C.I. 77577, Litharge, Lead(II) oxide
- REACH Information obligation: Yes