Schneider Electric

Contactor breaker TeSys U standard

TESYS U SCREW CLAMP BASE 12A LUB12
Article number: 
3231000
Suppl. article no: 
LUB12





 to see price and stock
Denna produkt innehåller ett eller flera ämnen på kandidatförteckningen.
TeSys model U is disconnectors, circuit breakers, contactors, overcurrent relay and communication module in a single unit, 45 mm wide. Tesys U meet international standards which IEC 947-6-2 ensures auto-coordination and continuous operation as well as the American standard UL508E (self protective motor starter).
Base unit for non-reversing starters.
The base units have two auxiliary contacts: 1 N/O (13-14) and 1 N/C (21-22) that indicate the end or open position for the main poles. They must be used in conjunction with protection module.
  • Article number: 
    3231000
  • Suppl. article no: 
    LUB12
  • Ean no: 
    3389110362770
  • Material class 
    QO360B
Technical data
  • Packagin Size: 1 ST/10 ST
  • Type: LUB12
  • Type of motor starter: Direct online starter (DOL)
  • Rated operation power at AC-3, 400 V: 5.5 kW
  • With short-circuit release: Yes
  • Rated control supply voltage AC 50 Hz: 24-240 V
  • Rated control supply voltage DC: 24-220 V
  • Rated operation current Ie: 12 A
  • Number of indicator lights: 0
  • Number of command positions: 3
  • Number of auxiliary contacts as normally open contact: 1
  • Number of auxiliary contacts as normally closed contact: 1
  • Width: 45 mm
  • Coordination class according to IEC 60947-4-3: Class 2
  • Depth: 126 mm
  • External reset possible: No
  • Type of electrical connection of main circuit: Screw connection
  • Height: 154 mm
  • Degree of protection (IP): IP20
  • Suitable for emergency stop: No
  • With fuse: No
  • With transformer: No
  • Rated operation power at AC-3, 230 V, 3-phase: 3 kW
  • Rated operation current at AC-3, 400 V: 12 A
  • Rated power, 460 V, 60 Hz, 3-phase: 5.5 kW
  • Rated power, 575 V, 60 Hz, 3-phase: 5.5 kW
  • Rated control supply voltage AC 60 Hz: 24-240 V
  • Ambient temperature, upper operating limit: 70 °C
  • Suitable for rail mounting: Yes
  • Voltage type for actuating: AC/DC
  • Supporting protocol for AS-Interface Safety at Work: No
  • Supporting protocol for ASI: No
  • Supporting protocol for CAN: No
  • Supporting protocol for Data-Highway: No
  • Supporting protocol for DeviceNet: No
  • Supporting protocol for DeviceNet Safety: No
  • Supporting protocol for EtherNet/IP: No
  • Supporting protocol for Foundation Fieldbus: No
  • Supporting protocol for INTERBUS: No
  • Supporting protocol for INTERBUS-Safety: No
  • Supporting protocol for LON: No
  • Supporting protocol for Modbus: No
  • Supporting protocol for PROFIBUS: No
  • Supporting protocol for PROFINET CBA: No
  • Supporting protocol for PROFINET IO: No
  • Supporting protocol for PROFIsafe: No
  • Supporting protocol for SERCOS: No
  • Supporting protocol for SUCONET: No
  • Supporting protocol for SafetyBUS p: No
  • Supporting protocol for TCP/IP: No
  • Supporting protocol for other bus systems: No
  • Type of electrical connection for auxiliary- and control current circuit: Screw connection
  • Rated conditional short-circuit current, type 1, 480 Y/277 V: 10000 A
  • Rated conditional short-circuit current, type 1, 600 Y/347 V: 4000 A
  • Rated conditional short-circuit current, type 2, 230 V: 50000 A
  • Rated conditional short-circuit current, type 2, 400 V: 50000 A
  • REACH contains candidate substances: Bly
  • REACH Date: 2022-07-20
  • REACH Information obligation: Yes
  • Rated data = 690 V: 12 A
  • Rated data = 500 V: 12 A