Feedback
Schneider Electric
Encased contacts LE1-D
ENCLOS 1S 09A 230V 50/60 LE1D09P7A04
Article number: Suppl. article no:
3233904
LE1D09P7A04
to see price and stock
Nested contactor without push buttons. Location of overcurrent relay. D09-D35 is plastic encapsulated. D40-D150 is sheet metal encapsulated
- Article number: 3233904
- Suppl. article no: LE1D09P7A04
- Ean no: 3389110570847
- Material class QO360B
Technical data
- Packagin Size: 1 ST/30 ST
- Type: LE1D09P7A04
- Design: Plastic encased
- Type of motor starter: Direct online starter (DOL)
- Rated operation power at AC-3, 400 V: 4 kW
- With short-circuit release: No
- Rated control supply voltage AC 50 Hz: 230 V
- Rated operation current Ie: 9 A
- Number of indicator lights: 0
- Number of command positions: 0
- Number of auxiliary contacts as normally open contact: 0
- Number of auxiliary contacts as normally closed contact: 0
- Width: 88 mm
- Depth: 120 mm
- External reset possible: No
- Type of electrical connection of main circuit: Screw connection
- Height: 166 mm
- Degree of protection (IP): IP65
- Suitable for emergency stop: No
- With fuse: No
- With transformer: No
- Rated operation power at AC-3, 230 V, 3-phase: 2.2 kW
- Rated operation current at AC-3, 400 V: 9 A
- Rated power, 460 V, 60 Hz, 3-phase: 4 kW
- Rated power, 575 V, 60 Hz, 3-phase: 5.5 kW
- Rated control supply voltage AC 60 Hz: 230 V
- Ambient temperature, upper operating limit: 40 °C
- Suitable for rail mounting: No
- Voltage type for actuating: AC
- Supporting protocol for AS-Interface Safety at Work: No
- Supporting protocol for ASI: No
- Supporting protocol for CAN: No
- Supporting protocol for Data-Highway: No
- Supporting protocol for DeviceNet: No
- Supporting protocol for DeviceNet Safety: No
- Supporting protocol for EtherNet/IP: No
- Supporting protocol for Foundation Fieldbus: No
- Supporting protocol for INTERBUS: No
- Supporting protocol for INTERBUS-Safety: No
- Supporting protocol for LON: No
- Supporting protocol for Modbus: No
- Supporting protocol for PROFIBUS: No
- Supporting protocol for PROFINET CBA: No
- Supporting protocol for PROFINET IO: No
- Supporting protocol for PROFIsafe: No
- Supporting protocol for SERCOS: No
- Supporting protocol for SUCONET: No
- Supporting protocol for SafetyBUS p: No
- Supporting protocol for TCP/IP: No
- Supporting protocol for other bus systems: No
- Type of electrical connection for auxiliary- and control current circuit: Screw connection
- Rated operation current Ie at AC-3, 400 V: 9 A
- REACH Date: 2022-07-20
- Number of normally open contacts as main contact: 3
- REACH Information obligation: No