Flame-resistant installation cable

Ahlsell helps you find quality cables for telecom, data, and other cable installation. Our assortment provides all kinds of cables, whether you work outdoors or indoors. We have connection cables, control cables, and power cables. Here you will also find cables for damp or explosive areas, which can withstand chemicals, acids, and alkalis. If you are looking for an insulated cable joint, you will also find this. Explore our wide range of cables here in Ahlsell's online store or visit your nearest Ahlsell shop.

Installation cable fire-resistant Novosafe 450/750 V, Rutab
Rutab
Installation cable fire-resistant Novosafe 450/750 V, Rutab
Art. no.: 0477000
Fire-resistant, halogen-free installation cable is intended for fixed installation with high fire safety requirements. Suitable for installation in public buildings such as schools, hospitals, shops, etc. In the event of fire, the cable maintains its electrical function for at least 90 minutes (PH90). Complies with flame-spread class IEC 60332-3-22 (F4A). Halogen-free IEC 60754-2, Flame-proof IEC 60332-1. Low smoke development IEC 61034-2. Fire-proof IEC 60331-11,-21,-23, PH 90 (90 min, 830°C).
Technical data:
Cable type: Novosafe S-FE-180/PH90
Operating voltage: 450/750V
Line construction: Single-wired blank copper cl.1
Line insulation: Cermaic silicon rubber
Outer jacket: Halogen-free special mixture, Orange.
Temperature range: -40°C - +80 °C
Lowest installation temperature: -10° C
Flammability class: IEC 60332-3-22 (F4A)
Installation cable, shielded, fire-resistant Novosafe 300/500 V, Rutab
Rutab
Installation cable, shielded, fire-resistant Novosafe 300/500 V, Rutab
Art. no.: 0477080
Fire-resistant halogen-free installation and fire alarm cable in shielded design. Intended for permanent installation in buildings for the public such as schools, hospital shops, etc. Suitable for use in fire alarm systems, control systems and in other installations where high demands are made on fire safety. its electrical function for at least 90 minutes (PH90) Complies with fire spreading class IEC 60332-3-22 (F4A) Halogen-free IEC 60754-2 Flameproof IEC 60332-1 Low smoke generation IEC 61034-2, Fireproof IEC 60331-11, -21 , -23, PH 90 (90 min, 830 ° C) Color: Red

Cable type: Novosafe S (St) -FE-180 / PH90
Operating voltage: 300/500 V
Conductor structure: One-piece shiny copper at 1 p.m.
Conductor insulation: Ceramic silicone rubber
Shade: Aluminum / polyester foil with tinned image guide
Outer sheath: Halogen-free special mixture, Red
Temperature range: -40 ° C - + 80 ° C
Minimum placement temperature: -10 ° C
Fire spread class: IEC 60332-3-22 (F4A)
Installation cable, shielded, fire-resistant Novosafe 300/500 V, Rutab